TY - JOUR
T1 - Wearable cardioverter defibrillator for preventing sudden cardiac death in patients at risk: An updated systematic review of comparative effectiveness and safety.
AU - Goetz, Gregor
AU - Wernly, Bernhard
AU - Wild, Claudia
N1 - Lehr-KH Teaching Hospital of the Paracelsus Medical University Salzburg, General Hospital Oberndorf, Paracelsus Medical University Salzburg, Oberndorf, Austria
Wernly: Institute of general practice, family medicine and preventive medicine, Strubergasse 21, 5020 Paracelsus Medical University, Salzburg, Austria
PY - 2023/4
Y1 - 2023/4
N2 - Objectives: To synthesise the available evidence of wearable cardioverter defibrillator (WCD) therapy as an add-on measure to optimal medical therapy (OMT) or as a replacement of hospital stay. Methods: An update systematic review (SR) of comparative effectiveness and safety of WCD therapy was con-ducted. We included randomised controlled trials (RCT), prospective comparative studies and prospective un-controlled studies with at least 100 patients. A narrative synthesis of the evidence was conducted.Results: One RCT (n = 2348) and further eleven observational studies (n = 5345) fulfilled our inclusion criteria. In the only available RCT, the use of the WCD was not statistically associated with a clinical benefit on arrhythmic mortality in post-myocardial infarction (MI) patients with an ejection fraction of <= 35%. The compliance with WCD therapy was low in the RCT and high in observational studies, with ten observational studies reporting on a daily wear time between 20 and 23.5 h. The range of percentage of patients receiving at least one appropriate shock was 1-4.8% and the rate of first shock success was reported to be 100% in three studies. Serious adverse events (SAEs) such as inappropriate shocks occurred rarely, with between 0% and 2% of patients being inap-propriately shocked within ten observational studies. In one of the observational studies, two patients (2%) were allergic to nickel developing skin rash and false alarms occurred in 58 patients (57%) in this study. Another registry study (n = 448) reported milder AEs, such as dermatitis and pressure marks, occurring in 0.9% and 0.2% of enrolled patients, respectively. Conclusion: The only available RCT failed to show superiority of add-on use of WCD in post MI patients. Observational evidence shows that the compliance with WCD is good, but the evidence is afflicted with selection bias and the inclusion of diverse mixed patient populations diluting the ability to draw indication-specific conclusions on the utility of the device. More comparative data is needed to justify continuing or expanding use of WCD therapy.
AB - Objectives: To synthesise the available evidence of wearable cardioverter defibrillator (WCD) therapy as an add-on measure to optimal medical therapy (OMT) or as a replacement of hospital stay. Methods: An update systematic review (SR) of comparative effectiveness and safety of WCD therapy was con-ducted. We included randomised controlled trials (RCT), prospective comparative studies and prospective un-controlled studies with at least 100 patients. A narrative synthesis of the evidence was conducted.Results: One RCT (n = 2348) and further eleven observational studies (n = 5345) fulfilled our inclusion criteria. In the only available RCT, the use of the WCD was not statistically associated with a clinical benefit on arrhythmic mortality in post-myocardial infarction (MI) patients with an ejection fraction of <= 35%. The compliance with WCD therapy was low in the RCT and high in observational studies, with ten observational studies reporting on a daily wear time between 20 and 23.5 h. The range of percentage of patients receiving at least one appropriate shock was 1-4.8% and the rate of first shock success was reported to be 100% in three studies. Serious adverse events (SAEs) such as inappropriate shocks occurred rarely, with between 0% and 2% of patients being inap-propriately shocked within ten observational studies. In one of the observational studies, two patients (2%) were allergic to nickel developing skin rash and false alarms occurred in 58 patients (57%) in this study. Another registry study (n = 448) reported milder AEs, such as dermatitis and pressure marks, occurring in 0.9% and 0.2% of enrolled patients, respectively. Conclusion: The only available RCT failed to show superiority of add-on use of WCD in post MI patients. Observational evidence shows that the compliance with WCD is good, but the evidence is afflicted with selection bias and the inclusion of diverse mixed patient populations diluting the ability to draw indication-specific conclusions on the utility of the device. More comparative data is needed to justify continuing or expanding use of WCD therapy.
KW - HEALTH TECHNOLOGY-ASSESSMENT
KW - HEART-FAILURE
KW - EUROPEAN-SOCIETY
KW - GUIDELINES
KW - THERAPY
KW - Sudden cardiac arrest
KW - Wearable)
KW - (cardioverter-) defibrillator (external
KW - Ventricular tachycardia
KW - Countershock
KW - Ventricular fibrillation
U2 - 10.1016/j.ijcha.2023.101189
DO - 10.1016/j.ijcha.2023.101189
M3 - Review article
C2 - 37025482
SN - 2352-9067
VL - 45
SP - 101189
JO - IJC HEART & VASCULATURE
JF - IJC HEART & VASCULATURE
ER -