Skip to main navigation Skip to search Skip to main content

Comparison of four D-dimer assays in the context of venous thromboembolism in the emergency department

  • Fabio Del Ben
  • , Elisabetta Fontanini
  • , Gabriella Azzarini
  • , Marina Arini
  • , Christian Marini
  • , Giovanni Poli
  • , Paola Pradella
  • , Serena Parusso
  • , Liliana Santarossa
  • , Federica Targa
  • , Lorena Zardo
  • , Roberta Giacomello
  • , Benedetto Morelli
  • Foundation IRCCS National Cancer Institute
  • Dipartimento di Area Medica
  • Componente del gruppo di studio Emostasi e Trombosi della Società Italiana di Biochimica Clinica e Biologia Molecolare Clinica-Medicina di Laboratorio (SIBioC)
  • Laboratorio Analisi
  • Dipartimento Area di Emergenza
  • UOC Laboratorio Analisi
  • Laboratorio di Patologia dell'Emostasi
  • Dipartimento di Medicina Trasfusionale ed Ematologia
  • Centro per le malattie emorragiche e trombotiche
  • Laboratorio Centrale di Patologia Clinica
  • Dipartimento di Medicina Specialistica
  • Coordinatore del gruppo di studio Emostasi e Trombosi della Società Italiana di Biochimica Clinica e Biologia Molecolare Clinica-Medicina di Laboratorio (SIBioC)

Research output: Contribution to journal › Original Article › peer-review

Abstract

INTRODUCTION: This observational study conducted across seven emergency care units compares the efficacy of four D-dimer detection methods, namely HemosIL D-dimer HS (HS), HemosIL D-dimer HS-500 (HS-500), VIDAS D-dimer (VIDAS), and HemosIL AcuStar D-dimer (ACUSTAR). The primary focus is on patients with a clinical suspicion of deep venous thrombosis (DVT) or pulmonary embolism (PE).

METHODS: A total of 149 samples were collected from patients with suspected DVT or PE. The confirmation of DVT/PE was based on calf ultrasound or computed tomography-Angiography. Direct comparisons were made between the different detection methods, considering both their analytical performance and clinical utility. Additionally, the impact of an age-adjusted cut-off on the diagnostic accuracy of each method was assessed.

RESULTS: The results revealed comparable negative predictive value, sensitivity, and specificity across the methods, with a notable exception of increased specificity for HS compared with HS-500 (50.8% vs. 41.5%, p = 0.03). Further analysis incorporating an age-adjusted cut-off demonstrated a significant improvement in specificity for HS. When using the age-adjusted cut-off, HS exhibited a substantial increase in specificity compared with HS-500 (63.1% vs. 49.2%, p = 0.004) and demonstrated significantly higher specificity compared with VIDAS (63.1% vs. 53.8%, p = 0.04).

CONCLUSION: The study emphasizes the nonuniversal effect of an age-adjusted cut-off and discusses the potential necessity for different cut-off values, particularly in the case of HS-500. These findings contribute to the understanding of D-dimer detection methods in the context of DVT and PE, providing insights into their relative performances and the potential optimization through age-adjusted cut-offs.

Original languageEnglish
Pages (from-to)936-945
Number of pages10
JournalInternational journal of laboratory hematology
Volume46
Issue number5
DOIs
Publication statusPublished - Oct 2024

Keywords

  • Humans
  • Fibrin Fibrinogen Degradation Products/analysis
  • Female
  • Male
  • Middle Aged
  • Emergency Service, Hospital
  • Aged
  • Venous Thromboembolism/diagnosis
  • Pulmonary Embolism/diagnosis
  • Sensitivity and Specificity
  • Adult
  • Aged, 80 and over
  • Venous Thrombosis/diagnosis

Fingerprint

Dive into the research topics of 'Comparison of four D-dimer assays in the context of venous thromboembolism in the emergency department'. Together they form a unique fingerprint.

Cite this