@article{58723ab0fa0a48c49c2c85968bca7c15,
title = "Small bowel obstruction after TAPP repair caused by a self-anchoring barbed suture device for peritoneal closure: case report and review of the literature.",
keywords = "LAPAROSCOPIC TRANSABDOMINAL PREPERITONEAL, INGUINAL-HERNIA REPAIR, GASTRIC BYPASS, FIBRIN GLUE, V-LOC, TRIAL, FIXATION, SURGERY, SAFE",
author = "G K{\"o}hler and Franz Mayer and Michael Lechner and R Bittner",
note = " Department of Surgery, Paracelsus Medical University, Salzburg, Austria",
year = "2015",
doi = "10.1007/s10029-014-1301-1",
language = "English",
volume = "19",
pages = "389--394",
journal = "Hernia : the journal of hernias and abdominal wall surgery",
issn = "1265-4906",
publisher = "Springer Nature",
number = "3",
}