T1 - Reproducibility for isometric and isokinetic maximum knee flexion and extension measurements using the IsoMed 2000-dynamometer
AU - Dirnberger, Johannes
AU - Wiesinger, Hans-Peter
AU - Koesters, Alexander
AU - Mueller, Erich
PY - 2012
Y1 - 2012
N2 - The present study was conducted to evaluate the relative and absolute reproducibility of the IsoMed 2000-dynamometer in measuring Peak Torque (PT) during maximum isometric and isokinetic (60 and 120 degrees/s) knee flexion and extension. Thirty four physically active male subjects (mean age: 23.2 years) were measured in three sessions (T1-T3), 48-72 h apart. Repeated measures analysis of variance (ANOVA) with Bonferroni post hoc adjustments revealed significant systematic errors for isokinetic flexion measurements with mean values on the second and third visit being around 3-5% higher than the corresponding values obtained in the first visit. Intraclass correlation coefficients (ICC 2,1) of 0.90-0.98 and 0.94-0.98 combined with values of standard error of measurement (SEM) of 5.5-9.1 and 4.0-9.0 Nm were found for T1-T2 and T2-T3, respectively. Based on the systematic errors found for flexor measurements and a clear improvement in reproducibility parameters from T1-T2 to T2-T3 for nearly all measurements, we recommend the use of a familiarisation session prior to actual testing.
AB - The present study was conducted to evaluate the relative and absolute reproducibility of the IsoMed 2000-dynamometer in measuring Peak Torque (PT) during maximum isometric and isokinetic (60 and 120 degrees/s) knee flexion and extension. Thirty four physically active male subjects (mean age: 23.2 years) were measured in three sessions (T1-T3), 48-72 h apart. Repeated measures analysis of variance (ANOVA) with Bonferroni post hoc adjustments revealed significant systematic errors for isokinetic flexion measurements with mean values on the second and third visit being around 3-5% higher than the corresponding values obtained in the first visit. Intraclass correlation coefficients (ICC 2,1) of 0.90-0.98 and 0.94-0.98 combined with values of standard error of measurement (SEM) of 5.5-9.1 and 4.0-9.0 Nm were found for T1-T2 and T2-T3, respectively. Based on the systematic errors found for flexor measurements and a clear improvement in reproducibility parameters from T1-T2 to T2-T3 for nearly all measurements, we recommend the use of a familiarisation session prior to actual testing.
KW - IsoMed 2000-dynamometer
KW - Reproducibility
KW - Isometric and isokinetic maximum strength testing
KW - Knee flexion and extension
UR - https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=pmu_pure&SrcAuth=WosAPI&KeyUT=WOS:000308457200001&DestLinkType=FullRecord&DestApp=WOS
U2 - 10.3233/IES-2012-0451
DO - 10.3233/IES-2012-0451
M3 - Original Article
SN - 0959-3020
VL - 20
SP - 149
EP - 153
JO - ISOKINET EXERC SCI
JF - ISOKINET EXERC SCI
IS - 3